Currents Distribution During a Fault in an MV Network: Methods and Measurements
2016
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighboring substations. In this paper the problem of fault current distribution is introduced, the tes…
On the hazardous situations due to the presence of HV/MV substations in urban areas
2017
The paper focuses on the hazardous situations that can rise in urban areas in case of earth fault inside a High Voltage/Medium Voltage station. IEEE and IEC/EN Standards and technical documents are examined and discussed, in order to propose some practical guidelines for a safe integration of such installations in contexts characterized by the presence of low voltage systems and not trained persons.
A Method to Evaluate Voltages to Earth During an Earth Fault in an HV Network in a System of Interconnected Earth Electrodes of MV/LV Substations
2008
An easy and swift method to evaluate, in a system of interconnected earth electrodes, earth potentials on earthing systems of medium-voltage/low-voltage (MV/LV) substations, in an event of single-line-to-earth fault inside a high-voltage/medium- voltage (HV/MV) station, is presented. The advantage of the method is the simplicity of the mathematical model for solving complex systems of any size with a sufficient accuracy for practical purposes. This paper shows the results of simulations, performed on networks with different extensions and characteristics, organized in easy-to-read graphs and tables. A comparison of these results with the values obtained according to the procedure explained …
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…